docs: v4.0.0 confirmed in game; drop wrong crew claim
Radiators carry no crew; CommandConsumer is command points. Status section records the in-game confirmation of all four behaviours. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_011oLWY1G6S8U35bi2FxVWni
This commit is contained in:
@@ -72,8 +72,7 @@ The radiator's own on/off switch picks a mode:
|
||||
vents only when it is nearly full: vent while less than **5%** of the
|
||||
network's heat storage is free, hold again once **10%** is free (a deadband
|
||||
so radiators do not chatter). The ship never overflows heat onto its own
|
||||
parts, and thermal batteries stay topped up as a deep missile reserve. An
|
||||
OFF radiator also releases its crew.
|
||||
parts, and thermal batteries stay topped up as a deep missile reserve.
|
||||
|
||||
The radiator measures the network itself, with a bare `NetworkResourceInput`
|
||||
— the same component an overclocked part pushes its heat through
|
||||
@@ -142,16 +141,15 @@ Switch it **ON** and it runs constantly, exactly as in vanilla.
|
||||
|
||||
## Status
|
||||
|
||||
**Release path confirmed, switch semantics not yet.** Against game 0.30.4c on
|
||||
2026-08-29, v3.0.0 in a real fight: radiators idled while the network filled,
|
||||
vented as it neared full, the ship never overheated, and they went quiet again
|
||||
once missiles drained the reserve.
|
||||
**Confirmed working.** Against game 0.30.4c on 2026-08-29, v4.0.0 in a real
|
||||
fight: radiators switched OFF idle while the network fills, vent as it nears
|
||||
full, the ship never overheats, and they go quiet again once missiles drain
|
||||
the reserve. Switched ON they vent constantly, as in vanilla.
|
||||
|
||||
v4.0.0 changed only the gate: earlier builds required a launcher to broadcast
|
||||
"thermal ammo in use" over the heat network, which worked at load but did not
|
||||
follow the ammo selection live. The player's switch expresses the intent more
|
||||
directly, so the broadcast was removed and OFF now means "bank heat". That
|
||||
switch behaviour is the one thing v4.0.0 has not been played with yet.
|
||||
Earlier builds required a launcher to broadcast "thermal ammo in use" over the
|
||||
heat network, which worked at load but did not follow the ammo selection live.
|
||||
The player's switch expresses the intent more directly, so the broadcast was
|
||||
removed in v4.0.0 and OFF now means "bank heat".
|
||||
|
||||
### What the assembly says
|
||||
|
||||
|
||||
@@ -34,7 +34,7 @@ Description = "Radiators switched OFF bank heat and vent only when the ship's he
|
||||
"- ON: vanilla. Vents constantly, the heat is gone.\n\n"\
|
||||
"- OFF: banks heat as a deep missile reserve. The radiator idles while the heat "\
|
||||
"network has room and vents as it approaches full, so the ship never overflows "\
|
||||
"heat onto its own parts. An OFF radiator also frees its crew.\n\n"\
|
||||
"heat onto its own parts.\n\n"\
|
||||
"- Fail-safe: idling requires measured headroom on the network. If that runs low, "\
|
||||
"or cannot be measured at all, radiators vent."
|
||||
|
||||
|
||||
Reference in New Issue
Block a user