Files
cosmoteer-pressure-relief-r…/components/radiator_auto.rules
T
TotenKnopfandClaude Opus 5 d82b7e43a4 feat: v2.0.0 -- confirmed working, scaffolding removed
Confirmed in game. The radiator's thermal-ammo and hold signals both
arrive, VentAllowed goes false, and the radiator idles with its manual
switch still on -- heat banked for the launchers instead of vented.

The self-test probes did their job: ThresholdToggle was fine, and a
mod-defined category carries a value perfectly well. The EMP probe was
simply a bad probe -- it read thermal_load_dissipation, which an idled
radiator broadcasts as zero, so it was correctly reporting a real zero.
Routing in v1.3.0 was the actual cure.

Remove the probes and the diagnostic indicators. The repointed power
indicator is the one cue a player needs: it now shows on a radiator the
mod has idled.

Add test_override_values_name_real_components, which catches an Overrides
value naming a component that does not exist -- a fourth way to produce a
mod that loads clean and does nothing, and one this very commit
introduced while stripping the scaffolding.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_011oLWY1G6S8U35bi2FxVWni
2026-08-29 00:27:25 +02:00

96 lines
2.6 KiB
Plaintext

// ABOUT ME
// Components merged into the Radiator. They receive the three network values
// this mod broadcasts and combine them into a single gate, AutoPowerToggle,
// which mod.rules then substitutes for the radiator's vanilla PowerToggle on
// the parts of the radiator that actually dissipate heat.
//
// Each broadcast arrives as a number, 1 or 0, summarised across the network by
// a NetworkValueReceiver and turned back into a toggle by a threshold at 0.5.
// A network with no broadcaster at all yields 0, which is why a ship without
// thermal batteries or thermal launchers keeps vanilla behaviour.
//
// The player's manual on/off switch (PowerToggle) is preserved and still wins:
// a radiator the player has switched off stays off. The automation can only
// idle a radiator the player has left on.
//
// A radiator vents when ANY of these hold:
// - the network is not asking it to hold (no battery, or battery full)
// - no launcher on the network is using thermal ammunition
// - some part is overflowing heat right now (safety net, overrides all)
AutoRad_HoldSignal
{
Type = NetworkValueReceiver
Categories = [ auto_radiator_hold ]
Mode = Max
AllowUncategorized = false
}
AutoRad_ThermalAmmoSignal
{
Type = NetworkValueReceiver
Categories = [ auto_radiator_ammo_user ]
Mode = Max
AllowUncategorized = false
}
AutoRad_ForceVentSignal
{
Type = NetworkValueReceiver
Categories = [ auto_radiator_force_vent ]
Mode = Max
AllowUncategorized = false
}
// "value is not zero", written the way vanilla writes it (the thermal pump's
// UtilizationToggle). The signals are only ever 0 or 1, so this is equivalent
// to a 0.5 threshold while sticking to a form the game demonstrably honours.
AutoRad_IsHolding
{
Type = ThresholdToggle
ValueFrom = AutoRad_HoldSignal
MinAmount = 0
MaxAmount = 0
Invert = true
}
AutoRad_ThermalAmmoInUse
{
Type = ThresholdToggle
ValueFrom = AutoRad_ThermalAmmoSignal
MinAmount = 0
MaxAmount = 0
Invert = true
}
AutoRad_ForceVent
{
Type = ThresholdToggle
ValueFrom = AutoRad_ForceVentSignal
MinAmount = 0
MaxAmount = 0
Invert = true
}
AutoRad_VentAllowed
{
Type = MultiToggle
Toggles
[
{ Toggle = AutoRad_IsHolding; Invert = true }
{ Toggle = AutoRad_ThermalAmmoInUse; Invert = true }
AutoRad_ForceVent
]
Mode = Any
}
// The replacement gate. PowerToggle is the radiator's vanilla UIToggle, so the
// player's switch remains the master control: it can turn a radiator off, and
// the automation can only idle one the player has left on.
AutoPowerToggle
{
Type = MultiToggle
Toggles = [ PowerToggle, AutoRad_VentAllowed ]
Mode = All
}